THERMOSTAT INSPECTION
PROCEDURE
INSPECT THERMOSTAT
Tip:The valve opening temperature is inscribed on the thermostat.
-
Immerse the thermostat in water and then gradually heat the water.
Check that the valve of the thermostat opens at the specified temperature.
Standard Valve Opening Temperature
80 to 84°C (176 to 183°F)
If the valve does not open as specified, replace the thermostat.
-
*a
Valve Lift
Check the valve lift.
Standard Valve Lift
10 mm (0.39 in.) or more at 82°C (180°F)
If the valve lift is not as specified, replace the thermostat.
Check that the valve is fully closed when the thermostat is at low temperatures (below 77°C (171°F)).
If the valve is not fully closed, replace the thermostat.
-