2WW BATTERY / CHARGING SERVICE DATA
Battery |
Standard Specific Gravity |
1.25 or higher at 20°C (68°F) |
Standard Voltage |
12.3 V or higher at 20°C (68°F) |
|
Fuse |
Standard Resistance |
Below 1 Ω |
Charging circuit without load |
Standard Current |
10 A or higher |
Standard Voltage |
12.1 to 15.4 V |
|
Charging circuit with load |
Standard Current |
30 A or higher |
Tester Connection |
Condition |
Specified Condition |
|---|---|---|
B126-1 (LIN) - A58-6 (LIN1) |
Always |
Below 1 Ω |
B126-1 (LIN) or A58-6 (LIN1) - Body ground |
Ignition switch off (while LIN communication is stopped) |
10 kΩ or higher |
Generator brush holder assembly |
Brush length |
Standard exposed length |
11.2 mm (0.441 in.) |
Minimum exposed length |
2.0 mm (0.0787 in.) |