2WW BATTERY / CHARGING SERVICE DATA

Battery

Standard Specific Gravity

1.25 or higher at 20°C (68°F)

Standard Voltage

12.3 V or higher at 20°C (68°F)

Fuse

Standard Resistance

Below 1 Ω

Charging circuit without load

Standard Current

10 A or higher

Standard Voltage

12.1 to 15.4 V

Charging circuit with load

Standard Current

30 A or higher

Table 1. HARNESS AND CONNECTOR

B126-1 (LIN) or A58-6 (LIN1) - Body ground

Tester Connection

Condition

Specified Condition

B126-1 (LIN) - A58-6 (LIN1)

Always

Below 1 Ω

B126-1 (LIN) or A58-6 (LIN1) - Body ground

Ignition switch off

(while LIN communication is stopped)

10 kΩ or higher

Table 2. GENERATOR ASSEMBLY

Generator brush holder assembly

Brush length

Standard exposed length

11.2 mm (0.441 in.)

Minimum exposed length

2.0 mm (0.0787 in.)