LIGHTING SYSTEM Interior Light Power Source Circuit
| DTC Code | DTC Name |
|---|---|
| Interior Light Power Source Circuit |
DESCRIPTION
The main body ECU (multiplex network body ECU) controls operation of the DOME CUT relay in order to supply power to the interior lights.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Inspect the fuses for circuits related to this system before performing the following procedure.
PROCEDURE
INSPECT DOME CUT RELAY
Remove the DOME CUT relay from the No. 4 relay block.
Inspect the DOME CUT relay.
OK
DOME CUT relay is normal.
Result
Proceed to
OK
NG
NG REPLACE DOME CUT RELAY
CHECK HARNESS AND CONNECTOR (BATTERY - DOME CUT RELAY)
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Condition
Specified Condition
No. 4 relay block DOME CUT relay holder terminal 2 - Body ground
Always
11 to 14 V
No. 4 relay block DOME CUT relay holder terminal 5 - Body ground
Always
11 to 14 V
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK HARNESS AND CONNECTOR (DOME CUT RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
Disconnect the 3C instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
No. 4 relay block DOME CUT relay holder terminal 3 - 3C-21
Always
Below 1 Ω
3C-21 - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK HARNESS AND CONNECTOR (DOME CUT RELAY - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
Disconnect the E22 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
No. 4 relay block DOME CUT relay holder terminal 1 - E22-15 (DOMR)
Always
Below 1 Ω
E22-15 (DOMR) - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Remove the instrument panel junction block assembly.
for RHD:Click hereClick here
for LHD:Click hereClick here
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
*a
Component without harness connected
(Instrument Panel Junction Block Assembly)
-
-
Standard Resistance
Tester Connection
Condition
Specified Condition
3C-21 - MB-3 (BCYL)
Always
Below 1 Ω
3C-42 - MB-3 (BCYL)
Always
Below 1 Ω
3E-38 - MB-4 (BCTL)
Always
Below 1 Ω
Result
Proceed to
OK
NG
NG REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
for RHD:Click hereClick here