FRONT DOOR LOCK INSPECTION
PROCEDURE
INSPECT FRONT DOOR LOCK ASSEMBLY LH (w/o Double Locking System)
Check the door lock motor operation.
Apply battery voltage to the motor connector and check the operation of the door lock motor.
OK
Measurement Condition
Specified Condition
Battery positive (+) → 4 (L)
Battery negative (-) → 1 (UL)
Lock
Battery positive (+) → 1 (UL)
Battery negative (-) → 4 (L)
Unlock
If the result is not as specified, replace the door lock assembly.
Check the detection switch.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
8 (LSSR) - 7 (E)
Lock
10 kΩ or higher
8 (LSSR) - 7 (E)
Unlock
Below 1 Ω
If the result is not as specified, replace the door lock assembly.
for LHD:
Check the door lock and unlock switch.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
9 (L) - 7 (E)
Lock
Below 1 Ω
9 (L) - 7 (E)
10 (UL) - 7 (E)
Off
10 kΩ or higher
10 (UL) - 7 (E)
Unlock
Below 1 Ω
If the result is not as specified, replace the door lock assembly.
INSPECT FRONT DOOR LOCK ASSEMBLY LH (w/ Double Locking System)
Check the door lock motor operation.
Apply battery voltage to the motor connector and check the operation of the door lock motor.
OK
Measurement Condition
Specified Condition
Battery positive (+) → 4 (L)
Battery negative (-) → 3 (UL)
Lock
Battery positive (+) → 3 (UL)
Battery negative (-) → 4 (L)
Unlock
Battery positive (+) → 2 (DL)
Battery negative (-) → 1 (UNDL)
Set
Battery positive (+) → 1 (UNDL)
Battery negative (-) → 2 (DL)
Unset
If the result is not as specified, replace the door lock assembly.
Check the detection switch.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
8 (LSSR) - 7 (E)
Lock
10 kΩ or higher
8 (LSSR) - 7 (E)
Unlock
Below 1 Ω
If the result is not as specified, replace the door lock assembly.
INSPECT FRONT DOOR LOCK ASSEMBLY RH (w/o Double Locking System)
Check the door lock motor operation.
Apply battery voltage to the door lock motor connector and check the operation of the door lock motor.
OK
Measurement Condition
Specified Condition
Battery positive (+) → 4 (L)
Battery negative (-) → 1 (UL)
Lock
Battery positive (+) → 1 (UL)
Battery negative (-) → 4 (L)
Unlock
If the result is not as specified, replace the door lock assembly.
Check the detection switch.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
7 (LSSR) - 8 (E)
Lock
10 kΩ or higher
7 (LSSR) - 8 (E)
Unlock
Below 1 Ω
If the result is not as specified, replace the door lock assembly.
for RHD:
Check the door lock and unlock switch.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
6 (L) - 8 (E)
Lock
Below 1 Ω
6 (L) - 8 (E)
5 (UL) - 8 (E)
Off
10 kΩ or higher
5 (UL) - 8 (E)
Unlock
Below 1 Ω
If the result is not as specified, replace the door lock assembly.
INSPECT FRONT DOOR LOCK ASSEMBLY RH (w/ Double Locking System)
Check the door lock motor operation.
Apply battery voltage to the door lock motor connector and check the operation of the door lock motor.
OK
Measurement Condition
Specified Condition
Battery positive (+) → 2 (L)
Battery negative (-) → 1 (UL)
Lock
Battery positive (+) → 1 (UL)
Battery negative (-) → 2 (L)
Unlock
Battery positive (+) → 4 (DL)
Battery negative (-) → 3 (UNDL)
Set
Battery positive (+) → 3 (UNDL)
Battery negative (-) → 4 (DL)
Unset
If the result is not as specified, replace the door lock assembly.
Check the detection switch.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
7 (LSSR) - 8 (E)
Lock
10 kΩ or higher
7 (LSSR) - 8 (E)
Unlock
Below 1 Ω
If the result is not as specified, replace the door lock assembly.
for RHD:
Check the door lock and unlock switch.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Switch Condition
Specified Condition
6 (L) - 8 (E)
Lock
Below 1 Ω
6 (L) - 8 (E)
5 (UL) - 8 (E)
Off
10 kΩ or higher
5 (UL) - 8 (E)
Unlock
Below 1 Ω
If the result is not as specified, replace the door lock assembly.