AIR CONDITIONING UNIT (for Manual Air Conditioning System) INSPECTION


  1. INSPECT AIR CONDITIONING RADIATOR ASSEMBLY (w/ PTC Heater)


    1. A01DX47E02
      Text in Illustration
      *a

      Component without harness connected

      (Air Conditioning Radiator Assembly (Max Hot Switch))

      *b OFF
      *c ON

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      1 - 2 ON Below 1 Ω
      1 - 2 OFF 10 kΩ or higher

      If the result is not as specified, replace the air conditioning radiator assembly (max hot switch).