AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) Weak Blower Output

DESCRIPTION

If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control panel (radio and display receiver assembly)*1 or air conditioning control assembly*2, the following factors may be the cause.

Symptom Factor

  • Airflow volume is constantly low

  • Airflow volume sometimes becomes low


  • Blower motor with fan sub-assembly malfunction

  • Clogged clean air filter

  • Clogged No. 1 evaporator sub-assembly or heater radiator unit sub-assembly fins

  • No. 1 cooler thermistor malfunction

  • ECO mode control of air conditioning system is enabled*3

  • Aspirator not connected properly


PROCEDURE


  1. CHECK AIR CONDITIONING SYSTEM


    1. Operate the blower switch with the following conditions met and check that the airflow volume changes.

      Blower Speed Condition
      LO → HI
      • Temperature setting: MAX COLD

      • Air outlet mode: FACE

      • A/C switch: Off

      OK
      Airflow volume increases.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CONFIRM MODEL

    Result
    Result Proceed to
    w/ ECO Switch A
    w/o ECO Switch B

    B
    A
  3. CHECK ECO MODE SETTING


    1. Check if the ECO mode indicator is off.

      OK
      The ECO mode indicator is off.
      Result
      Proceed to
      OK
      NG

    OK
    NG
  4. CONFIRM MODEL

    Result
    Result Proceed to
    w/ ECO Switch Assembly (electric parking brake switch assembly) A
    w/ ECO switch assembly (air conditioning control panel (radio and display receiver assembly)) B
    w/ ECO switch assembly (air conditioning control assembly) C

    B
    C
    A
  5. CHECK ECO MODE CONTROL OPERATION


    1. Operate the ECO switch assembly (electric parking brake switch assembly) and check that the ECO mode indicator turns off and the blower speed reduction is canceled.

      Tech Tips


      • When ECO mode control is operating, the air conditioning amplifier assembly controls the air conditioning system to enhance fuel efficiency. Therefore, explain to the customer that, when ECO mode control is operating, the blower speed will be reduced.

        Control Outline
        Blower Control When the air conditioning system is in AUTO mode, the blower speed will be reduced to a certain speed. Additionally, if warm-up control is operating, the blower speed will be further reduced.
        Air Inlet Control If the ambient temperature is a certain value or more, the air inlet mode will be changed to recirculation mode.
      • In some situations, ECO mode control may not operate even though it is enabled.

      Result
      Result Proceed to
      ECO mode indicator turns off and blower speed reduction is canceled A
      ECO mode indicator turns off, but the blower speed reduction is not canceled B
      ECO mode indicator does not turn off

    A
    B
  6. CHECK ECO MODE CONTROL OPERATION


    1. Operate the ECO switch assembly (air conditioning control panel (radio and display receiver assembly)) and check that the ECO mode indicator turns off and the blower speed reduction is canceled.

      Tech Tips


      • When ECO mode control is operating, the air conditioning amplifier assembly controls the air conditioning system to enhance fuel efficiency. Therefore, explain to the customer that, when ECO mode control is operating, the blower speed will be reduced.

        Control Outline
        Blower Control When the air conditioning system is in AUTO mode, the blower speed will be reduced to a certain speed. Additionally, if warm-up control is operating, the blower speed will be further reduced.
        Air Inlet Control If the ambient temperature is a certain value or more, the air inlet mode will be changed to recirculation mode.
      • In some situations, ECO mode control may not operate even though it is enabled.

      Result
      Result Proceed to
      ECO mode indicator turns off and blower speed reduction is canceled A
      ECO mode indicator turns off, but the blower speed reduction is not canceled B
      ECO mode indicator does not turn off C

    A
    B
    C
  7. CHECK ECO MODE CONTROL OPERATION


    1. Operate the ECO switch assembly (air conditioning control assembly) and check that the ECO mode indicator turns off and the blower speed reduction is canceled.

      Tech Tips


      • When ECO mode control is operating, the air conditioning amplifier assembly controls the air conditioning system to enhance fuel efficiency. Therefore, explain to the customer that, when ECO mode control is operating, the blower speed will be reduced.

        Control Outline
        Blower Control When the air conditioning system is in AUTO mode, the blower speed will be reduced to a certain speed. Additionally, if warm-up control is operating, the blower speed will be further reduced.
        Air Inlet Control If the ambient temperature is a certain value or more, the air inlet mode will be changed to recirculation mode.
      • In some situations, ECO mode control may not operate even though it is enabled.

      Result
      Result Proceed to
      ECO mode indicator turns off and blower speed reduction is canceled A
      ECO mode indicator turns off, but the blower speed reduction is not canceled B
      ECO mode indicator does not turn off C

    B
    C
    A
  8. CHECK CLEAN AIR FILTER


    1. Visually check the clean air filter.

      Click here

      OK
      The clean air filter is not dirty or clogged.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  9. CHECK NO. 1 COOLER THERMISTOR


    1. Check the installation condition of the No. 1 cooler thermistor.

      OK
      The No. 1 cooler thermistor is installed correctly.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  10. CHECK ASPIRATOR


    1. Check the installation condition of the aspirator.

      OK
      The aspirator is installed correctly.
      Result
      Proceed to
      OK
      NG

    OK
    NG